RMI sensor
type
Temperature Type 1 Type 2 Type 3 Type 4
°C °F
40 104 291.5 480.7 69.3
50 122 197.3 323.6
60 140 134.0 222.5 36.0
70 158 97.1 157.1
80 176 70.1 113.2 19.8
90 194 51.2 83.2
100 212 38.5 62.4 11.7
110 230 29.1 47.6
120 248 22.4 36.8 7.4
130 266 28.9
140 284 22.8
150 302 18.2
The configurable type is configurable with eight points in the range 0-2500 Ω. The temperature
as well as the resistance can be adjusted.
7.20.7 RMI fuel
This RMI input is used for the fuel level sensor.
RMI sensor type
Type 1
Value Resistance
0% 78.8 Ω
100% 1.6 Ω
RMI sensor type
Type 2
Value Resistance
0% 3 Ω
100% 180 Ω