DAC-310 Delem
V0504, 10
If the value for step repetition CY is higher than 1, only the value
of CY in the current step is decremented by 1 and no new step
will be loaded.
When the Automatic key is pressed to start a program, the control
automatically starts at Step 1. This happens whether or not the
parameter ST is programmed higher than zero. See chapter 4 for
more information about parameter ST.
3.4. Semi-automatic mode
The semi-automatic mode serves to execute a program step by
step.
The Semi-automatic Mode is started with its
own start key.
The execution cycle of a step runs similar to the one in automatic
mode. There are the following differences.
• The DAC-310 stops at the end of each step.
• A program is started at the step that is currently selected.
If the programmed value for CY is higher than 1 a number of
cycles equal to this value must have been executed before the
DAC-310 stops.
In semi-automatic mode you can choose to execute a program
step by step or execute a number of steps from the memory. This
depends on the value of the ST parameter. This will be explained
in detail in chapter 4.