Delem
V0504, 13
Everytime a step is executed, the axis moves to the programmed
position Xm. The actual position is shown by Xp. When the axis
has reached position, Xp has the same value as Xm. Xp is then
highlighted on the display.
When the cursor is at Xm a value is displayed with a format
depending on machine settings.
Either millimetres or inches is possible.
Note:
The back gauge position can also be programmed negative. In
that case, it is considered as a chaining value.
4.3.4. COR(rection)
Correction on the programmed back gauge position.
The value to be programmed at COR appears in the same
resolution as Xm.
Default: 0
Note: the presence of this parameter depends on machine
settings
4.3.5. Retract distance DX
In some cases it may be necessary to clear (retract) the material
from the back gauge. This may occur at the moment when the
mechanical action begins. The retract distance is a programmable
displacement of the motor axis in the up counting direction.
The value at DX appears in the same resolution as Xm.
Default: 0
Note: the presence of this parameter depends on machine
settings