4. PARAMETER PROGRAMMING
4.1. Introduction
The DAC-310 is a programmable back gauge controller.
The DAC-310 can also program parameters, related to other
machine functions.
One such set of parameters is referred to as a "step".
Several steps can be combined to build a program. During the
execution of the program the steps within the program are
executed one after another in an automatic cycle. The control
switches to the next step when a Start/Enable signal is received.
4.2. Identification of a step
A step is identified by a number in the range 0-99. This means
that up to 100 steps can be programmed and stored into memory.
Step 0 is an exception. This step is the manual mode of the
control and is never part of any program.
The number of the selected step is displayed in the upper left
corner of the display.
The keys + and - are used to browse through the available steps.
Holding the keys + or - will speed up the effect.