Delem
V0504, 15
4.3.8. Stock Counter #
Range : -1 - 9999
Default: 0
Stock counter determines the number of times that the selected
program will be repeated (product counter).
There are two operation modes for the product counter:
- down counting
- up counting
When programmed to zero, the counter will count up. When
programmed larger than zero, the counter will count down. When
programmed to -1, there is no stock count.
During execution of a program the #-value is incremented or
decremented each time a program has been executed once.
If in the down counting mode the value zero has been reached
the DAC-310 stops and the cursor will automatically move to the
#-symbol. The programmed value is reloaded if the start button is
pressed.
In the up counting mode the #-value is incremented by 1 each
time the program has been executed once. When the #-value
reaches 9999 the next value will be zero.
This actual #-value will always be displayed.
4.3.9. Number of steps ST
Here you can program the number of steps of which a program
exists.
When programmed to zero, you can browse through all 99 steps
that are available in memory. If the Automatic key is pressed,
execution of steps is started at step 1 and will continue to step 99
or until the Stop key is pressed. If semi-automatic is pressed,
execution of steps is started from the currently selected step.
When ST is programmed higher than zero, the display shows the
number of steps and which step is currently active, e.g. 1/3. When
either Automatic or Semi-automatic is started, the steps of this
program are executed.