T
he main way to disconnect power from the system is to unplug the power supply cord.
The system includes two power supplies. To completely remove system power, you must disconnect both power supplies.
Always disconnect the power connections before moving the system.
If you think the unit is damaged in any way, permanently unplug it.
CAUTION:
The system components are heavy. To avoid personal injury and/or damage to the equipment, do
not attempt to install or remove system components without a mechanical lift and/or help from another
person.
A
DD9400 system weighs up to 63.05 lbs (28.6 kg).
DS60 shelves weigh up to 225 lbs (90.7 kg).
ES40 shelves weigh up to 68 lbs (30.8 kg).
FS25 shelves weigh up to 44.61 lbs (20.23 kg).
Working with a portable lift
If you are installing the shelf with all field replaceable units (FRUs) removed, you can install the shelf without using a lift. If you
need to install the shelf with FRUs onboard, use a portable lift.
Service personnel generally use the portable lift manufactured by Alum-A-Lift. Instructions for this lift are included in the lift kit.
http://www.corkc4.isus.emc.com/wiki/index.php/Lift_Tool describes the Lift equipment and the ordering process.
NOTE:
If you are using a portable lift other than the Alum-A-Lift, adapt these instructions as necessary while following all
required safety requirements.
Lift requirements
F
or installations in racks that are 28U (49 inches) or less above the floor, use the lower mast, which is rated for 400 pounds.
For installations in racks that are more than 28U (49 inches) above the floor, use the lower mast configuration and a support
table with the "Voyager" conversion kit, which is rated for 225 pounds.
Adjusting the arms for a frontal lift
About this task
If you plan to use the mechanical lift directly in front of the cabinet, adjust the width of the lift arm/tray to just under 17 inches
to ensure that the arms will stay under the chassis.
Steps
1. Adjust the two arms with rollers so that they are 17 inches apart measured from the outside edges.
2. Tighten the arms to secure them.
The following figure shows an example of adjusting the lift arm/tray to just under 17 inches.