Command syntax
secli (list failed drives | lfd) ([-a=<(SAS WWID | AdapterIndex)>] [-enc=<(WWN | EnclIndex)> [-
w= <DrawerIndex>]] [-outputformat=<SupportOutputFormats>] [-verbose] | -enc=<WWN> [-
outputformat=<SupportedOutputFormats>] [-verbose] | [-h])
Parameters
Table 18. List failed drives
Parameter Description
-a
Species the adapter used for the command. This is either SAS WWID or
AdapterIndex.
-enc
Species the enclosure used for the command. This is either WWN or EnclIndex.
-w
Species the drawer index used for the command.
-h
Provides more information about the command, description, and usage.
-outputformat
You can specify the following output formats: XML or JSON.
Command examples
list failed drives
list failed drives –a=0
list failed drives –enc=500a123456789012
Informational commands
Show adapter information
Description
This command provides information about the specied adapter and status or count of the attached devices.
Command syntax
shmcli (info adapter | infoadapter | ia) (-a=<(SAS WWID | AdapterIndex)> [-
outputformat=<SupportedOutputFormats>] | [-h])
Parameters
Table 19. Adapter information
Parameter Decription
-a
Species the adapter used for the command. This is either SAS
WWID or AdapterIndex.
-h
Provides information about the command, description, and usage.
-outputformat
You can specify the following output formats: XML or JSON.