PS6500 Hardware Maintenance Basic Array Information
1-5
Figure 1-8: LCD Panel – Disk Drive and Power Supply Failures
Table 1-1 describes the icons used in the LCD panel and the accompanying text.
Note: For detailed information about a hardware failure, use the Group Manager GUI to view the group event log.
Table 1-1: LCD Panel Hardware Icons
Icon Failure Text Description
Drive Fault n
Disk drive failure, where n specifies the drive number (0 to 47).
N/A Approximate location of failed disk drive. A PS6500 chassis has 12
columns of four disk drives. From left to right and from the front of the
array to the rear, the first column includes disk drives 0 to 3, the next
column includes disk drives 4 to 7, and so on.
PSU n Fault
Power supply and cooling module failure, where n (and the number
shown in the icon) specifies the module (
0, 1, or 2, numbered from left
to right when viewed from the rear of the array).
Fan n Fault
Fan failure in a power supply and cooling module, where n (and the
number shown in the icon) specifies the module (
0, 1, or 2, numbered
from left to right when viewed from the rear of the array).
Thermal Fault
Array temperature exceeds upper or lower limit.
I/O card n Fault
Control module failure, where n (and the number shown in the icon)
specifies the control module (
0 or 1, numbered from left to right when
viewed from the rear of the array).
EIP card Fault
EIP card has failed.
Channel Crd n Er
Channel card has failed, where n (and the number shown in the icon)
specifies the card (
0 or 1, numbered from right to left when viewed from
the front of the array).
Enclosure OPEN Chassis cover is open, exposing the disk drives.
Comms Fault The EIP card and active control module have not communicated for
more than 2.5 minutes.

Table of Contents