Site preparations
The S4048–ON is suitable for installation as part of a common bond network (CBN).
You can install the system in:
Network telecommunication facilities
Data centers
Other locations where the National Electric Code (NEC) applies
For more information about S4048–ON specications, see Specications.
NOTE: Install the S4048–ON system into a rack or cabinet before installing any optional components.
Topics:
Site selection
Cabinet placement
Rack mounting
System ground
Fans and airow
Power
Storing components
Site selection
Install Dell equipment in restricted access areas.
A restricted access area is one in which service personnel can only gain access using a special tool, lock, key or other means of security and
access is controlled by the authority responsible for the location.
Ensure that the area where you install your S4048–ON system meets the following safety requirements:
Near an adequate power source. Connect the system to the appropriate branch circuit protection as dened by your local electrical
codes.
Environmental temperature between 32° to 113°F (from 0° to 45°C).
The switch operating ambient temperature range is from 10° to 35°C (from 50° to 95°F).
Operating humidity is from 5 to 85 percent non-condensing.
Storage humidity is from 5 to 95 percent non-condensing.
In a dry, clean, well-ventilated and temperature-controlled room, away from heat sources such as hot air vents or direct sunlight.
Away from sources of severe electromagnetic noise.
Positioned in a rack or cabinet, or on a desktop with adequate space in the front, rear, and sides of the S4048–ON for proper
ventilation and access.
Cabinet placement
Install the S4048–ON only in indoor cabinets designed for use in a controlled environment.
Do not install the S4048–ON in outside cabinets. For cabinet placement requirements, see Site Selection.
3
12 Site preparations

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Networking S4048 and is the answer not in the manual?

Dell Networking S4048 Specifications

General IconGeneral
Uplink Ports6 x 40GbE QSFP+
Rack Units1 RU
Power SupplyDual, hot-swappable
AirflowFront-to-back or back-to-front
Form FactorRack-mountable
Jumbo Frame SupportYes, up to 9216 bytes
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
AC Input Voltage100-240 VAC
AC Input Frequency50/60 Hz
Switching Capacity1.44 Tbps
LatencyLess than 800 ns
Product TypeSwitch
Humidity10% to 90% (non-condensing)
Dimensions43.9 x 4.3 x 44.9 cm (17.3 x 1.7 x 17.7 in)
ManagementCLI, SNMP, Web UI
Layer SupportLayer 2 and Layer 3

Related product manuals