Chassis physical design
Table 5. Chassis physical design
Parameter Specications
Height 1.71 inches (43.5 mm)
Width 17.09 inches (434 mm)
Depth 18.11 inches (460 mm)
Chassis weight with factory-installed components 21.7 lbs (9.86 kg)
Rack clearance required
Front: 5 inches (12.7 cm)
Rear: 5 inches (12.7 cm)
Table 6. Environmental parameters
Parameter Specications
Operating temperature 32° to 113°F (0° to 45°C)
Operating humidity 5 to 85% (RH), non-condensing
Storage temperature –40° to 158°F (–40° to 70°C)
Storage humidity 5 to 95%, non-condensing
Maximum thermal output 1153.265 BTU/hr
Maximum operational altitude 10,000 feet (3,048 meters)
Maximum non-operational altitude No performance degradation to 35,000 feet (10,668 meters)
Shock Meets Bellcore Zone 4 earthquake requirements (MIL-STD-810)