6 Install the:
a heat sink assembly
b optical drive
c cooling shroud
d 2.5 hard drive assembly
e front bezel
f cover
7 Follow the procedure in After working inside your computer.
Intrusion switch
Removing intrusion switch
1 Follow the procedure in Before working inside your computer.
2 Remove the:
a cover
b front bezel
c cooling shroud
3 To the intrusion switch:
a Disconnect the intrusion switch cable from the connector on the system board [1].
b Slide the intrusion switch and push it to remove from the chassis [2].
Disassembly and reassembly