使用入门指南 33
步骤
1
:
The system is not setup for SNMP management by default. To manage
the switch using SNMP (required for Dell Network Manager) you can
(默认情况下,系统未设置为使用
SNMP
管理。要使用
SNMP
管理交换机
[Dell
Network Manager
要求
]
,您可以)
. Set up the initial SNMP version 2 account now.
(立即设置初始
SNMP
版本
2
帐户。)
. Return later and setup other SNMP accounts. (For more
information on setting up an SNMP version 1 or 3 account,
see the user documentation).
(稍后返回并设置其它
SNMP
帐户。
[
有关设置
SNMP
版本
1
或
3
帐户的详情,请参阅用户说明文件
]
。)
Would you like to setup the SNMP management interface now? [Y/N]
(是否立即设置
SNMP
管理接口?
[Y/N]
)
y
To setup the SNMP management account you must specify the
management system IP address and the "community string" or
password that the particular management system uses to access the
switch. The wizard automatically assigns the highest access level
[Privilege Level 15] to this account. You can use Dell Network
Manager or other management interfaces to change this setting and
to add additional management systems later. For more information
on adding management systems, see the User?s Guide.
(要设置
SNMP
管
理帐户,必须指定管理系统
IP
地址,以及
“团体字符串”或特定管理系统用于访问交换
机的密码。该向导将自动为此帐户分配最高级别的访问权限
[
权限级别
15]
。可以使用
Dell Network Manager
或其它管理接口更改这一设置,并且稍后添加其它管理系统。
有关添加管理系统的详情,请参阅 《用户指南》。
)
To add a management station:
(添加管理站:)
Please enter the SNMP community string to be used [public]:
(请输入
要使用的
SNMP
团体字符串
[public]
)
public
注:如果已配置,默认访问级别将设置为用于访问 SNMP 管理接口的最高权限级别。 最初将
仅激活 SNMPv1/2c。 将禁用 SNMPv3,直至返回而为 SNMPv3 配置安全访问(例如引擎 ID,
查看等)。
Please enter the IP address of the Management System (A.B.C.D) or
wildcard (0.0.0.0) to manage from any Management Station
{0.0.0.0}:
(请输入管理系统的
IP
地址
[A.B.C.D]
或通配符
[0.0.0.0]
以便从
任何管理站
{0.0.0.0}
进行管理:)
192.168.2.100