About Your System 129
PCI BIOS failed to
install.
Faulty or improperly
installed mezzanine card.
Reseat the mezzanine card.
See "I/O Module Mezzanine
Cards" on page 217. If the
problem persists, see
"Getting Help" on page 361.
Plug & Play
Configuration
Error.
Error encountered in
initializing PCI device;
faulty blade board.
Set the NVRAM_CLR
jumper to "on" and reboot
the blade. See
"Blade
System Board Jumper
Settings
" on page 331 for
the jumper location.
Check for a BIOS update. If
the problem persists, see
"Getting Help" on page 361.
PCIe Training
Error: Expected
Link Width is x',
Actual Link Width
is x
Faulty or improperly
installed PCIe card in the
specified slot.
Reseat the PCIe card in the
specified slot number. See
"Troubleshooting Expansion
Cards" on page 321. If the
problem persists, see
"Getting Help" on page 361.
ROM bad checksum =
address
Expansion card improperly
installed or faulty.
Ensure that the expansion
card is installed properly. See
"Troubleshooting Expansion
Cards" on page 321.
BIOS Update
Attempt Failed.
BIOS remote update
failed.
Retry the BIOS update. If
problem persists, see
"Getting Help" on page 361.
Invalid
configuration
information -
please run SETUP
program
CMOS checksum failure. Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and UEFI Boot Manager" on
page 137.
Table 1-27. Blade Messages
(continued)
Message Causes Corrective Actions