EasyManua.ls Logo

Dell PowerEdge R860 - Installing the LOM Card and Rear I;O Board

Dell PowerEdge R860
222 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Next steps
1. Replace the LOM card and rear I/O board.
Installing the LOM card and rear I/O board
Prerequisites
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in the Before working inside your system.
3. Remove the system board.
NOTE: The procedure to install the liquid cooling rear I/O board and rear I/O board is the same.
Steps
1. Align the connectors and slots on the LOM card or rear I/O board with the connector and standoffs on the system board.
2. Press the LOM card or rear I/O board until firmly seated on the system board connector.
3. Using a Phillips #2 screwdriver, secure the LOM card or rear I/O board to the system board with screws.
Figure 164. Installing the LOM card and rear I/O board
192
Installing and removing system components

Table of Contents

Related product manuals