After you have securely installed and powered on the switch, to configure your switch, see your third-party ONIE-compatible OS
or the Dell OS documentation.
Topics:
ONIE service discovery
ONIE service discovery
ONIE attempts to locate the installer through several discovery methods.
To download and run an installer, the ONIE Service Discovery feature follows these steps in order and uses the first successful
method found:
1. Search locally attached storage devices for one of the ONIE default installer filenamesfor example, onie self update
from the USB.
2. Query to the IPv6 link-local neighbors using HTTP for an installer.
3. Discover TFTP-based image from the DHCP server.
If none of the ONIE Service Discovery methods are successful, you can disable this using the onie-discovery-stop
command.
You can install an operating system manually from HTTP, FTP, or TFTP using the onie-nos-install <URL> command.
NOTE: If you have a recovery USB plugged into your switch, remove it before using the onie-nos-install command.
The ONIE Install environment uses DHCP to assign an IP address to the management interfaceeth0. If that fails, it uses the
default IP address 192.168.3.10/255.255.255.0.
To display the IP address, use the ifconfig eth0 command, as shown.
ONIE:/ # ifconfig eth0
eth0 Link encap:Ethernet HWaddr 90:B1:1C:F4:9C:76
inet addr:10.11.53.33 Bcast:10.255.255.255 Mask:255.0.0.0
inet6 addr: fe80::92b1:1cff:fef4:9c76/64 Scope:Link
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
RX packets:18 errors:0 dropped:0 overruns:0 frame:0
TX packets:24 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000
RX bytes:1152 (1.1 KiB) TX bytes:6864 (6.7 KiB)
Interrupt:21 Memory:ff300000-ff320000
To assign an IP address to the management interface, eth0, and verify network connectivity, use the ifconfig eth0 <ip
address> command, as shown.
ONIE:/ # ifconfig eth0 10.11.53.33/16
Verify the network connection with ping.
ONIE:/ # ping 10.11.8.12
PING 10.11.8.12 (10.11.8.12): 56 data bytes
64 bytes from 10.11.8.12: seq=0 ttl=62 time=1.357 ms
64 bytes from 10.11.8.12: seq=1 ttl=62 time=0.577 ms
^C
42
Before you install an OS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerSwitch S4128F-ON and is the answer not in the manual?

Dell PowerSwitch S4128F-ON Specifications

General IconGeneral
Product TypeSwitch
ModelS4128F-ON
Uplink Ports4 x 100GbE QSFP28
Power SupplyDual, hot-swappable
AirflowFront-to-back or back-to-front
Jumbo Frame SupportYes, up to 9216 bytes
Latency800ns
ManagementCLI, SNMP, REST API
Dimensions (W x D x H)43.0 cm x 4.3 cm