Specifications | 41
8
Specifications
This chapter contains the following sections:
Chassis Physical Design
Agency Compliance
Chassis Physical Design
Environmental Parameters
AC Power Requirements
Parameter Specifications
Height 1.73 inches (4.4 cm)
Width 17.32 inches (44.0 cm)
Depth 18.74 inches (47.6cm)
Chassis weight with factory-installed components 14.41 pounds (approx.) (6.54 kg)
Rack clearance required Front: 5-inches (12.7 cm)
Rear: 5-inches (12.7 cm)
Thermal dissipation 921 BTH/h (270W)
Power consumption 230 Watts (nominal)
270 Watts (maximum)
Parameter Specifications
Temperature 32° to 104°F (0° to 40°C)
-40° to 158°F (-20° to 70°C)
Maximum altitude No performance degradation to 10,000 feet (3,048 meters)
Relative humidity 10 to 85% non-condensing
Shock MIL-STD-810
Parameter Specifications
Nominal input voltage 100 to 240 VAC, 47-63 Hz
Maximum AC power supply input current 4.20 A @ 100VAC
1.70 A @ 240 VAC
Maximum system power input 350 W

Table of Contents

Other manuals for Dell S4810

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4810 and is the answer not in the manual?

Dell S4810 Specifications

General IconGeneral
Ports48 x 10GbE SFP+
Uplink Ports4 x 40GbE QSFP+
Switching Capacity1.28 Tbps
Rack Units1U
Product TypeSwitch
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyYes
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Power SupplyDual, hot-swappable
MAC Address Table Size128, 000 entries
Routing ProtocolOSPF, BGP, RIP, PIM, VRRP
Remote Management ProtocolSNMP
FeaturesVLAN, QoS
Humidity10% to 90% non-condensing
Dimensions (WxDxH)43.9 x 46.5 x 4.3 cm