Chapter 12 Application Examples |ASDA-A&A+ Series
Revision April 2009 12-23
(5) Manually Continuous Step Control Mode
Power
Supply
ON
OFF
DO VALUE
INDEX4
Motor Speed
IDX Value
ON
OFF
Torque
Limit
Servo ON
INDEX 2
CI INDEX 2 CI INDEX 3 CI INDEX 4 CI
INDEX 5
MD0
ON
OFF
ON
OFF
MD1
ON
OFF
MDP1
auto
running
manually feed
forward
NOTE
1) After manually feed forward operation is completed, please set MD1 and MD0 to be OFF and then turn
MDP0 from ON to OFF (ready to enter torque decrease status) to avoid any abnormal condition.
2) In manually feed forward mode (MDP0 is ON), if MD0 is ON, then the servo motor will continuous step
feed forward and if MD1 is ON, then the servo motor will continuous step feed reverse.
3) For manually single step operation speed, please refer to parameter P2-37.
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com
Call 1(800)985-6929 for Sales
deltaacdrives.com
sales@deltaacdrives.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASD-A2023MA and is the answer not in the manual?

Delta Electronics ASD-A2023MA Specifications

General IconGeneral
BrandDelta Electronics
ModelASD-A2023MA
CategoryDC Drives
LanguageEnglish

Related product manuals