Input Voltage | 24 VDC |
---|---|
Product Type | Remote Terminal Unit |
Communication Protocols | Modbus RTU |
Ethernet Ports | 1 x 10/100 Mbps |
Serial Ports | 1 x RS-485 |
Storage Temperature | -40°C to 85°C |
Humidity | 5% to 95% (non-condensing) |
Lists the key capabilities of the RTU-EN01 module, including smart PLC functions and network support.
Details the technical specifications for Ethernet, RS-232, and RS-485 interfaces, environment, and electrical characteristics.
Provides physical dimensions and an overview of the RTU-EN01 module's components.
Explains LED indicators and defines pinouts for communication interfaces (RJ-45, RS-232, RS-485).
Describes the function of the RUN/STOP switch for device operation control.
Guides on connecting the RTU-EN01 to DVP Slim series digital I/O modules.
Provides instructions for mounting the RTU-EN01 and I/O modules onto a 35mm DIN rail.
Explains the process of connecting the RTU-EN01 module to the network via Ethernet.
Lists and defines the basic read/write registers (BR) for module configuration and status.
Provides detailed explanations for each basic register (BR) and their specific usage.
Describes external input (RX) and output (RY) contacts and control registers (RCR).
Details word and bit devices for timer (T) and counter (C) functions.
Lists and explains the bit devices used for the real-time clock (RTC) functions.
Lists the Modbus function codes supported by the RTU-EN01 module.
Lists the Modbus exception codes that may be returned by the RTU-EN01 module.
Defines device types and their corresponding Modbus addresses for discrete and holding registers.
Guides on establishing communication and searching for RTU-EN01 modules using DCISoft.
Explains how to add and manage IP addresses in DCISoft for module identification.
Covers module naming, network configuration, and communication timers in DCISoft.
Details how to configure network settings on the PC, including static IP assignment.
Guides on configuring the RTU-EN01 to synchronize its real-time clock with a time server.
Explains how to configure IP filtering to restrict network access to the RTU-EN01.
Describes configuring independent Smart PLC logic using IF-THEN conditions and actions.
Details how to configure the timer functions within the Smart PLC feature.
Explains how to configure the counter functions within the Smart PLC feature.
Guides on setting up real-time clock (RTC) triggering for specific events.
Explains how to manage analog I/O modules and their control registers.
Describes how to monitor internal registers and I/O status in real-time.
Guides on configuring the RTU-EN01 to function as a Modbus TCP to RS-485 gateway.
Explains how to set up and use the Virtual COM feature for serial communication over Ethernet.
Details how to set up passwords to protect the RTU-EN01 configuration.
Guides on how to reset the RTU-EN01 settings to their factory default values.
Explains how to access and use the RTU-EN01 through a web browser.
Provides an example of setting up IF-THEN logic in Smart PLC using DCISoft.
Demonstrates timer configuration within Smart PLC for cyclic operations.
Illustrates counter configuration within Smart PLC for event counting.
Shows setting up real-time clock (RTC) triggering for daily cyclic operations.
Provides an example of using Virtual COM to connect to Delta VFDSoft software.