9_
Error code Description
CPU
Status
LED indicator
status
ERROR
BUS
FAULT
16#0028
The latching data register range which is set is incorrect.
Stop
ON
Keep
16#0029
The latching timer range which is set is incorrect.
Stop
ON
Keep
16#002A
The latching counter range which is set is incorrect.
Stop
ON
Keep
16#002B
The latching 32-bit counter range which is set is incorrect.
Stop
ON
Keep
16#0033
The communication setting of COM1 is incorrect. (SM9)
Continue
Blinking
Keep
16#0034
The setting of the station address of COM1 is incorrect. (SM9)
Continue
Blinking
Keep
16#0035
The setting of the communication type of COM1 is incorrect. (SM9)
Continue
Blinking
Keep
16#0038
The communication setting of COM2 is incorrect. (SM9)
Continue
Blinking
Keep
16#0039
The setting of the station address of COM2 is incorrect. (SM9)
Continue
Blinking
Keep
16#003A
The setting of the communication type of COM2 is incorrect. (SM9)
Continue
Blinking
Keep
16#0050
The memories in the latched special auxiliary relays are abnormal.
Stop
ON
Keep
16#0051
The latched special data registers are abnormal.
Stop
ON
Keep
16#0052
The memories in the latched auxiliary relays are abnormal.
Stop
ON
Keep
16#0053
The latched timers are abnormal.
Stop
ON
Keep
16#0054
The latched counters are abnormal.
Stop
ON
Keep
16#0055
The latched 32-bit counters are abnormal.
Stop
ON
Keep
16#0056
The memories in the latched timers are abnormal.
Stop
ON
Keep
16#0057
The memories in the latched counters are abnormal.
Stop
ON
Keep
16#0058
The memories in the latched 32-bit counters are abnormal.
Stop
ON
Keep
16#0059
The latched data registers are abnormal.
Stop
ON
Keep
16#005A
The latched working registers are abnormal.
Stop
ON
Keep
16#005E
The memory card is initialized incorrectly. (SM453)
Continue
Blinking
Keep
16#005F
The data is read from the inexistent file in the memory card, or the
data is written into the inexistent file in the memory card. (SM453)
Continue Blinking Keep
16#0061
The capacity of the memory card is not large enough. (SM453)
Continue
Blinking
Keep
16#0062
The memory card is write protected. (SM453)
Continue
Blinking
Keep
16#0063
An error occurs when the data is written into the memory card.
(SM453)
Continue Blinking Keep
16#0064
The file in the memory card can not be read. (SM453)
Continue
Blinking
Keep
16#0065
The file in the memory card is a read-only file. (SM453)
Continue
Blinking
Keep
16#0066
An error occurs when the system is backupped.
Continue
Blinking
Keep
16#0067
The length of the restored system data exceeds the system data
length of CPU module
Continue Blinking Keep
16#1401
An error occurs when the data in the I/O module is accessed. (SM9)
Stop
Keep
ON

Table of Contents

Other manuals for Delta AH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AH Series and is the answer not in the manual?

Delta AH Series Specifications

General IconGeneral
BrandDelta
ModelAH Series
CategoryController
LanguageEnglish

Related product manuals