How to fix Data range error occurs when accessing CANopen PDO in Delta ASD-A2-3043?
K
Karen StewartSep 18, 2025
To fix data range error occurs when accessing CANopen PDO in Delta Servo Drives, when the data value in the message is over the range of the specified object, use NMT: Reset node or 0x6040.Fault Reset.
K
kingdeborahAug 31, 2025
What causes overspeed in Delta Servo Drives?
C
Christy FlemingAug 31, 2025
Overspeed in Delta Servo Drives can be triggered by:
* Unstable speed input command (too much fluctuation). If this is the case, ensure that input command frequency is stable (not fluctuate too much) and activate filter function.
* Defective over-speed parameter setting. If this is the case, correctly set over-speed parameter setting (P2-34).
J
Joshua GarnerAug 27, 2025
What causes CANbus error on Delta ASD-A2-3043?
M
Matthew GriffinAug 27, 2025
A CANbus error on Delta Servo Drives is caused by CANbus off or Error Rx/Tx Counter exceeding 128. NMT Maser send “Reset node“ command to its slave or restart the servo drive.
L
Lauren ThomasSep 23, 2025
How to fix An error occurs when loading CANopen data in Delta Servo Drives?
K
Kelsey RamosSep 23, 2025
To fix an error occurs when loading CANopen data in Delta Servo Drives, when an error occurs when loading data via EEPROM, use DI.ARST, CANopen 0x1011 Restore default parameter.
D
Devin ReyesSep 23, 2025
How to resolve Error occurs when writing CANopen PDO via EEPROM in Delta ASD-A2-3043?
P
philliptaylorSep 23, 2025
To resolve error occurs when writing CANopen PDO via EEPROM in Delta Servo Drives, when an error occurs when saving the current value into ROM, use NMT: Reset node or 0x6040.Fault Reset.
B
Benjamin WilliamsSep 2, 2025
How to resolve a serial communication timeout on Delta ASD-A2-3043?
J
Joshua DawsonSep 2, 2025
A serial communication timeout on Delta Servo Drives can occur if:
* The setting value in the timeout parameter is not correct. If this is the case, correctly set P3-07.
* Communication command is not being received for a long time. If this is the case, tighten the communication cable, make sure the communication cable is not damaged and ensure all wiring is correct.
I
ivillarrealSep 5, 2025
What to do if CANopen PDO object does not support PDO on Delta ASD-A2-3043?
E
Emily ArcherSep 5, 2025
If the specified object in the message does not support PDO, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
C
Cynthia DavenportSep 9, 2025
What to do if Delta ASD-A2-3043 Servo Drives show abnormal pulse command?
F
fgarciaSep 9, 2025
If your Delta Servo Drives are showing an abnormal pulse command, it could be because the pulse command frequency is higher than the rated input frequency. Correctly set the input pulse frequency.
T
Thomas ChavezSep 16, 2025
How to resolve Encoder does not complete the command which is issued by servo drive in Delta Servo Drives?
R
Rebecca SmallSep 16, 2025
If your Delta Servo Drives are showing that the encoder does not complete the command which is issued by servo drive because servo drive has not completely written barcode into encoder or the encoder does not complete the command issued by servo drive, correct the wiring.
B
Brandon KingAug 25, 2025
What causes excessive deviation in Delta Servo Drives?
B
Brady ThompsonAug 26, 2025
Excessive deviation in Delta Servo Drives can be caused by:
* Maximum deviation parameter setting is too small. If this is the case, increase the parameter setting value of P2-35.
* Gain value is too small. If this is the case, correctly adjust gain value.
* Torque limit is too low. If this is the case, correctly adjust torque limit value.
* There is an overload. If this is the case, reduce external applied load or re-estimate the motor capacity.