How to resolve Error occurs when writing CANopen PDO via EEPROM in Delta ASD-A2-3043?
P
philliptaylorSep 23, 2025
To resolve error occurs when writing CANopen PDO via EEPROM in Delta Servo Drives, when an error occurs when saving the current value into ROM, use NMT: Reset node or 0x6040.Fault Reset.
S
Stephanie HernandezAug 27, 2025
What to do if data range error occurs when accessing CANopen PDO object on Delta ASD-A2-3043?
C
christopherpetersonAug 27, 2025
If the data in the message has exceeded the data range of the specified object, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
J
Joshua GarnerAug 27, 2025
What causes CANbus error on Delta ASD-A2-3043?
M
Matthew GriffinAug 27, 2025
A CANbus error on Delta Servo Drives is caused by CANbus off or Error Rx/Tx Counter exceeding 128. NMT Maser send “Reset node“ command to its slave or restart the servo drive.
G
grantbrandonSep 3, 2025
What to do if there is a U, V, W, GND wiring error on Delta Servo Drives?
T
Tiffany MosesSep 3, 2025
If there is a U, V, W, GND wiring error on Delta Servo Drives, it means that the wiring connections of U, V, W (for servo motor output) and GND (for grounding) are in error. Follow the wiring steps in the user manual to reconnect the wiring and ground the servo drive and motor properly.
I
ivillarrealSep 5, 2025
What to do if CANopen PDO object does not support PDO on Delta ASD-A2-3043?
E
Emily ArcherSep 5, 2025
If the specified object in the message does not support PDO, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
J
Joseph WoodSep 7, 2025
How to fix over current in Delta ASD-A2-3043?
J
Jordan EdwardsSep 7, 2025
If your Delta Servo Drive is showing an over current error, there are several potential causes and solutions:
* A short circuit in the drive output: Eliminate the short circuit, ensuring no metal conductors are exposed.
* Incorrect motor wiring: Rewire the motor following the wiring instructions in the user manual.
* A faulty IGBT: Send the drive back to the distributors or contact Delta.
* Incorrect control parameter settings: Reset to the default settings and then gradually adjust the values.
* Unreasonable command: Use a less steep command or apply a filter to smooth the command.
S
Sarah EvansSep 10, 2025
What to do if Delta Servo Drives show Adjustment Error?
S
shirleyfieldsSep 10, 2025
If your Delta Servo Drives are showing an adjustment error:
* The analog input contact is incorrectly set back to zero: Correctly ground the analog input contact.
* The detection device is damaged: If the error still occurs after reset, send the drive back to the distributors or contact with Delta.
M
Matthew GonzalesSep 14, 2025
What to do if Delta ASD-A2-3043 show Wrong setting of E-gear ratio?
C
Cameron SmithSep 14, 2025
If your Delta Servo Drives are showing the wrong setting of E-gear ratio because setting of E-gear ratio is wrong when power on the servo drive, modify the range of E-gear ratio and repower on the servo drive.
I
Ian ReyesSep 23, 2025
How to resolve The accessing address of EEPROM is out of range when using CANopen PDO in Delta Servo Drives?
R
Rachel MeltonSep 23, 2025
To resolve the accessing address of EEPROM is out of range when using CANopen PDO in Delta Servo Drives, when the quantity of the data inside ROM is over the planned space, use NMT: Reset node or 0x6040.Fault Reset.
B
Brandon KingAug 25, 2025
What causes excessive deviation in Delta Servo Drives?
B
Brady ThompsonAug 26, 2025
Excessive deviation in Delta Servo Drives can be caused by:
* Maximum deviation parameter setting is too small. If this is the case, increase the parameter setting value of P2-35.
* Gain value is too small. If this is the case, correctly adjust gain value.
* Torque limit is too low. If this is the case, correctly adjust torque limit value.
* There is an overload. If this is the case, reduce external applied load or re-estimate the motor capacity.