What to do if data type (size) error occurs when accessing CANopen object on Delta Servo Drives?
C
Catherine ComptonAug 29, 2025
If the data length in the message does not match the specified object, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
C
Courtney FarleyAug 30, 2025
What to do if data range error occurs when accessing CANopen object on Delta ASD-A2-3043?
D
Dr. Michelle Davis MDAug 30, 2025
If the data in the message has exceeded the data range of the specified object, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
J
Jennifer StantonAug 30, 2025
Why does my Delta Servo Drive show an overcurrent error?
C
Carla ChangAug 30, 2025
An overcurrent error in your Delta Servo Drive can occur due to several reasons:
* A short-circuit at the drive output (U, V, W). If this is the case, repair the short-circuited and avoid metal conductor being exposed.
* Motor wiring error. If this is the case, follow the wiring steps in the user manual to reconnect wiring.
* IGBT error. If this is the case, please contact your distributor for assistance or contact with Delta.
* Control parameter setting error. If this is the case, set the setting back to factory default setting and then reset and adjust the parameter setting again.
* Control command setting error. If this is the case, ensure that input command frequency is stable (too much fluctuation) and activate filter function.
D
Donna StewartSep 22, 2025
How to fix Parameter group of PR#8 is out of range in Delta Servo Drives?
B
Benjamin DouglasSep 22, 2025
To fix parameter group of PR#8 is out of range in Delta Servo Drives, when the parameter group of command source exceeds the range, use DI.Alm Reset or write 0 into P0-01.
T
Travis HarrisonSep 23, 2025
How to resolve Enter the incorrect password when using CANopen PDO in Delta ASD-A2-3043 Servo Drives?
J
Jessica HamiltonSep 23, 2025
To resolve enter the incorrect password when using CANopen PDO in Delta Servo Drives, when entering parameters via CAN, the parameters are password-protected, use NMT: Reset node or 0x6040.Fault Reset.
E
Elizabeth AbbottSep 12, 2025
What to do if Delta ASD-A2-3043 Servo Drives show Encoder voltage error or the internal of the encoder is in error?
C
cbestSep 12, 2025
If your Delta Servo Drives are showing encoder voltage error or the internal of the encoder is in error:
* Battery voltage is too high: According to the procedure of Over voltage to check. When corrective actions are done, AL.028 will be cleared automatically.
* The internal encoder is in error: If the situation is not improving, please send the drive back to the distributors or contact with Delta.
K
kingdeborahAug 31, 2025
What causes overspeed in Delta Servo Drives?
C
Christy FlemingAug 31, 2025
Overspeed in Delta Servo Drives can be triggered by:
* Unstable speed input command (too much fluctuation). If this is the case, ensure that input command frequency is stable (not fluctuate too much) and activate filter function.
* Defective over-speed parameter setting. If this is the case, correctly set over-speed parameter setting (P2-34).
W
william42Aug 31, 2025
How do I fix an encoder error on Delta Servo Drives?
D
Douglas BrownAug 31, 2025
An encoder error (position detector fault) on Delta Servo Drives can be due to:
* Incorrect encoder wiring. If this is the case, ensure all wiring is correct.
* A loose encoder. If this is the case, install the motor again.
* Defective encoder wiring. If this is the case, conduct the wiring again.
* A damaged encoder. If this is the case, replace the motor.
M
Meghan JonesSep 1, 2025
What to do if Delta Servo Drives display an adjustment error?
M
martin32Sep 1, 2025
If your Delta Servo Drives display an adjustment error, it might be because:
* The analog input contact does not go back to zero. If this is the case, correctly ground the analog input contact.
* The detection device is damaged. If the error persists after resetting the power supply, please contact your distributor or Delta for assistance.
W
walkersaraSep 1, 2025
What causes a reverse limit switch error on Delta ASD-A2-3043?
J
Jacob HartSep 1, 2025
A reverse limit switch error on Delta Servo Drives can be triggered by:
* The reverse limit switch being activated. If this is the case, activate reverse limit switch.
* An unstable servo system. If this is the case, modify parameter setting and re-estimate motor capacity.