A CANbus error on Delta Servo Drives is caused by CANbus off or Error Rx/Tx Counter exceeding 128. NMT Maser send “Reset node“ command to its slave or restart the servo drive.
C
Cynthia DavenportSep 9, 2025
What to do if Delta ASD-A2-3043 Servo Drives show abnormal pulse command?
F
fgarciaSep 9, 2025
If your Delta Servo Drives are showing an abnormal pulse command, it could be because the pulse command frequency is higher than the rated input frequency. Correctly set the input pulse frequency.
N
noahbrownAug 27, 2025
What to do if write parameter error occurs: exceeds the limit of normal range on Delta ASD-A2-3043 Servo Drives?
S
shawandrewAug 27, 2025
If the parameter setting value exceeds the limit of normal range, correct the PR command and parameter setting value.
L
Lauren ThomasSep 23, 2025
How to fix An error occurs when loading CANopen data in Delta Servo Drives?
K
Kelsey RamosSep 23, 2025
To fix an error occurs when loading CANopen data in Delta Servo Drives, when an error occurs when loading data via EEPROM, use DI.ARST, CANopen 0x1011 Restore default parameter.
M
Michael SkinnerSep 16, 2025
How to fix regeneration error in Delta Servo Drives?
R
Rachael RamirezSep 16, 2025
If your Delta Servo Drives are showing a regeneration error because you choose the wrong regenerative resistor or does not connect to external regenerative resistor, calculate the value of the regenerative resistor again and correctly set the value of P1-52 and P1-53.
E
Elizabeth AbbottSep 12, 2025
What to do if Delta ASD-A2-3043 Servo Drives show Encoder voltage error or the internal of the encoder is in error?
C
cbestSep 12, 2025
If your Delta Servo Drives are showing encoder voltage error or the internal of the encoder is in error:
* Battery voltage is too high: According to the procedure of Over voltage to check. When corrective actions are done, AL.028 will be cleared automatically.
* The internal encoder is in error: If the situation is not improving, please send the drive back to the distributors or contact with Delta.
K
Keith OlsenSep 19, 2025
How to resolve CANopen PDO is read-only and write-protected in Delta Servo Drives?
A
ashleyrothSep 22, 2025
To resolve CANopen PDO is read-only and write-protected in Delta Servo Drives, when the specified object in the message is write- protected, use NMT: Reset node or 0x6040.Fault Reset.
S
Samantha McmahonSep 22, 2025
How to resolve CANopen PDO is not allowed in PDO in Delta ASD-A2-3043 Servo Drives?
G
gjohnsonSep 22, 2025
To resolve CANopen PDO is not allowed in PDO in Delta Servo Drives, when the specified object in the message does not support PDO, use NMT: Reset node or 0x6040.Fault Reset.
J
Jason CooperAug 29, 2025
What to do if index error occurs when accessing CANopen object on Delta Servo Drives?
L
Lee PerezAug 29, 2025
If the specified Index in the message does not exist, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).
K
Kathryn LittleAug 29, 2025
What to do if sub-index error occurs when accessing CANopen object on Delta ASD-A2-3043?
A
Alexander OliverAug 29, 2025
If the specified Sub-index in the message does not exist, NMT Maser send “Reset node“ command to its slave or reset the fault by sending the control word (0x6040) through CAN communication (the value of CANopen object 0x6040 should be reset).