Why is my Delta Servo Drives showing a reverse limit error?
J
Jimmy WallsSep 12, 2025
A reverse limit error on your Delta Servo Drives can occur because:
* The reverse limit switch is activated: Enable the reverse limit switch.
* The servo system is unstable: Re-adjust the parameter or evaluate the motor capacity.
R
Ruben AguilarSep 12, 2025
What does 'Forward Limit Error' mean on Delta ASD-A2-3043 Servo Drives?
K
Katherine BrownSep 12, 2025
A forward limit error on Delta Servo Drives indicates:
* The forward limit switch is activated: Enable the forward limit switch.
* The servo system is unstable: Re-adjust the parameter or evaluate the motor capacity.
M
Mary WellsSep 12, 2025
What to do if Delta ASD-A2-3043 Servo Drives show The internal of the encoder is in error?
R
Robin Davis MDSep 12, 2025
If your Delta Servo Drives are showing that the internal of the encoder is in error:
* The internal of the encoder is in error. (The internal memory and the internal counter are in error): If issue persists, please send the drive back to the distributors or contact with Delta.
* When power on, the motor operates because of mechanical inertia or other causes: When power on, please make sure the motor shaft stands still and will not operate.
T
Tonya NguyenSep 12, 2025
What causes abnormal EEPROM in Delta ASD-A2-3043?
C
Carlos TranSep 12, 2025
If your Delta Servo Drives are showing an abnormal EEPROM:
* It is in error when DSP accesses EEPROM: The fault occurs when applying to the power. It means one of the parameters is over the reasonable range. Please re-power on after adjusting. The fault occurs in normal operation. It means it is in error when writing the parameter. The alarm can be cleared by DI.ARST.
* Abnormal hidden parameter: Please set the correct type of the drive.
* Data in ROM is damaged: Please send the drive back to the distributors or contact with Delta.
W
wattsbonnieSep 12, 2025
What causes Abnormal Signal Output in Delta ASD-A2-3043 Servo Drives?
J
jonesnormaSep 12, 2025
If your Delta Servo Drives are showing abnormal signal output:
* The encoder is in error and cause the abnormal signal output: Conduct the corrective actions of AL.011, AL.024, AL.025, AL.026.
* The output pulse exceeds the hardware allowable range: Correctly set parameter P1-76 and P1-46.
C
Cody GomezSep 12, 2025
How to troubleshoot serial communication error in Delta ASD-A2-3043?
A
allisonterrySep 12, 2025
If you're experiencing a serial communication error with your Delta Servo Drives, check the following:
* Improper setting of the communication parameter: Correctly set the parameter value.
* Incorrect communication address: Correctly set the communication address.
* Incorrect communication value: Correctly set the value.
E
Elizabeth AbbottSep 12, 2025
What to do if Delta ASD-A2-3043 Servo Drives show Encoder voltage error or the internal of the encoder is in error?
C
cbestSep 12, 2025
If your Delta Servo Drives are showing encoder voltage error or the internal of the encoder is in error:
* Battery voltage is too high: According to the procedure of Over voltage to check. When corrective actions are done, AL.028 will be cleared automatically.
* The internal encoder is in error: If the situation is not improving, please send the drive back to the distributors or contact with Delta.
K
Keith HamiltonSep 12, 2025
What causes serial communication time out in Delta ASD-A2-3043?
D
David GarciaSep 12, 2025
A serial communication timeout error in Delta Servo Drives can occur due to:
* Improper setting of the time-out parameter: Correctly set the value.
* The drive hasn’t received the communication command for a long time: Correct wiring.
H
hugheswandaSep 12, 2025
What does main circuit power lack phase mean for Delta Servo Drives?
N
Nicholas MullinsSep 12, 2025
If your Delta Servo Drives are showing main circuit power lack phase, the main circuit power is abnormal. Make sure it applies to the power. If issue persists, please send the drive back to the distributors or contact with Delta.
U
udicksonSep 13, 2025
How to fix incorrect wiring of the motor power line U, V, W in Delta ASD-A2-3043?
P
powersheatherSep 13, 2025
If your Delta Servo Drives are showing incorrect wiring of the motor power line U, V, W because the wiring of U, V, W of the motor is incorrectly connected or the connection is breakdown, follow the user manual to correctly wire U, V, and W and make sure it is grounded.