Loading...
Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-57
P1-28
VSG2
Low-frequency Vibration Suppression
Gain (2)
Address: 0138H
0139H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
0
Control
Mode
PT / PR
Unit
-
Range
0 ~ 9 (0: Disable the second
low-frequency filter)
Data Size
16bit
Format
DEC
Settings
The second low-frequency vibration suppression gain. The
bigger value it is, the better the position response will be.
However, if the value is set too big, the motor will not be able to
smoothly operate. It is suggested to set the value to 1.
P1-29
AVSM
Auto Low-frequency Vibration Supression
Setting
Address: 013AH
013BH
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
0
Control
Mode
PT / PR
Unit
-
Range
0 ~ 1
Data Size
16bit
Format
DEC
Settings
0: The function is disabled.
1: The value will set back to 0 after vibration suppression.
Description of Auto Mode Setting:
When the parameter is set to 1, it is in auto suppression. When
the vibration frequency is not being detected or the value of
searched frequency is stable, the parameter will set to 0 and save
the low-frequency vibration suppression to P1-25 automatically.
P1-30
VCL Low-frequency Vibration Detection
Address: 013CH
013DH
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
500