Chapter 8 ParametersASDA-A2R Series
8-56 Revision December, 2014
Range
10 ~ 1000
Data Size
16bit
Format
DEC
Example
150= 15 Hz
Settings
The setting value of the first low-frequency vibration suppression.
If P1-26 is set to 0, then it will disable the first low-frequency filter.
P1-26
VSG1
Low-frequency Vibration Suppression
Gain (1)
Address: 0134H
0135H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
0
Control
Mode
PT / PR
Unit
-
Range
0 ~ 9 (0: Disable the first low-frequency
filter)
Data Size
16bit
Format
DEC
Settings
The first low-frequency vibration suppression gain. The bigger
value it is, the better the position response will be. However, if the
value is set too big, the motor will not be able to smoothly operate.
It is suggested to set the value to 1.
P1-27
VSF2 Low-frequency Vibration Suppression (2)
Address: 0136H
0137H
Operational
Interface
Panel / Software Communication
Related Section:
6.2.9
Default
1000
Control
Mode
PT / PR
Unit
0.1 Hz
Range
10 ~ 1000
Data Size
16bit
Format
DEC
Example
150 = 15 Hz
Settings
The setting value of the second low-frequency vibration
suppression. If P1-28 is set to 0, then it will disable the second
low-frequency filter.