Chapter 8 ParametersASDA-A2R Series
Revision December, 2014
8-137
Settings
Users manually adjust the OFFSET
P4-24 LVL Level of Undervoltage Error
Address: 0430H
0431H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
160
Control
Mode
ALL
Unit
V (rms)
Range
140~190
Data Size
16bit
Format
DEC
Settings
When the voltage of DC BUS is lower than P4-24*
2
, the
undervoltage alarm occurs.

Table of Contents