DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
2-74
Starting address of the Connection to be read, written or connected.*
D1363
D1423
D1364
D1424
D1365
D1425
D1366
D1426
D1367
D1427
D1368
D1428
D1369
D1429
D1370
D1430
M1355 = ON, Connection status is user-defined. Activate the Connection manually with M1368~M1375.
M1355 = OFF, Connection status is auto-detected. Monitor if the connection is established and activated with M1368~M1375.
M1368
M1369
M1370
M1371
M1372
M1373
M1374
M1375
Communication status of Connection ID#9-16 on PLC LINK (ON: communicating)
M1384
M1385
M1386
M1387
M1388
M1389
M1390
M1391
Error flag for errors occurred when reading or writing on Connection ID#9-16(ON = normal; OFF = error)
M1400
M1401
M1402
M1403
M1404
M1405
M1406
M1407
Reading complete on PLC LINK Connection ID#9-16 (System resets to OFF after reading is complete on one module.)
M1416
M1417
M1418
M1419
M1420
M1421
M1422
M1423
Writing complete on PLC LINK connection ID#9-16 (System resets to OFF after writing is complete on one module.)
M1432
M1433
M1434
M1435
M1436
M1437
M1438
M1439
↓
↓
↓
↓
↓
↓
↓
↓
Slave PLC*
CONNECTION
ID 9
CONNECTION
ID 10
CONNECTION
ID 11
CONNECTION
ID 12
CONNECTION
ID 13
CONNECTION
ID 14
CONNECTION
ID 15
CONNECTION
ID 16
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
4. Special D and special M corresponding to Connection ID1~ID8: (M1353 = ON, access
available for up to 50 words) (DVP-12SE V1.6 and DVP-26SE V2.0 supports 100 words at
most.)
MASTER PLC
CONNECTION
ID 1
CONNECTION
ID 2
CONNECTION
ID 3
CONNECTION
ID 4
CONNECTION
ID 5
CONNECTION
ID 6
CONNECTION
ID 7
CONNECTION
ID 8
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
M1353 = ON, enable access up to 50 words.
The user can specify the starting register for storing the read/written data in registers below.
D1480
D1496
D1481
D1497
D1482
D1498
D1483
D1499
D1484
D1500
D1485
D1501
D1486
D1502
D1487
D1503
M1356 = ON, the user can specify the station number of Connection ID1~ID8 in D1900~D1907
D1900
D1901
D1902
D1903
D1904
D1905
D1906
D1907
Data length to be read/written for connections (Max 50 pieces of data; 0: no reading/writing)
D1434
D1450
D1435
D1451
D1436
D1452
D1437
D1453
D1438
D1454
D1439
D1455
D1440
D1456
D1441
D1457
Starting address of the Connection to be read, written or connected.*
D1355
D1415
D1356
D1416
D1357
D1417
D1358
D1418
D1359
D1419
D1360
D1420
D1361
D1421
D1362
D1422
M1355 = ON, Connection status is user-defined. Activate the Connection manually with M1360~M1367.
M1355 = OFF, Connection status is auto-detected. Monitor if the connection is established and activated with M1360~M1367.
M1360
M1361
M1362
M1363
M1364
M1365
M1366
M1367
Communication status of Connection ID#1-8 on PLC LINK (ON: communicating)
M1376
M1377
M1378
M1379
M1380
M1381
M1382
M1383
Error flag for errors occurred when reading or writing on Connection ID#1-8 (ON = normal; OFF = error)
M1392
M1393
M1394
M1395
M1396
M1397
M1398
M1399
Reading complete on PLC LINK Connection ID#1-8 (System resets to OFF after reading is complete on one module.)
M1408
M1409
M1410
M1411
M1412
M1413
M1414
M1415
Writing complete on PLC LINK connection ID#1-8 (System resets to OFF after writing is complete on one module.)
M1424
M1425
M1426
M1427
M1428
M1429
M1430
M1431
↓
↓
↓
↓
↓
↓
↓
↓
Slave PLC*
CONNECTION
ID 1
CONNECTION
ID 2
CONNECTION
ID 3
CONNECTION
ID 4
CONNECTION
ID 5
CONNECTION
ID 6
CONNECTION
ID 7
CONNECTION
ID 8
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
Read
out
Write
in
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215
D100
│
D115
D200
│
D215

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-EX2 and is the answer not in the manual?

Delta DVP-EX2 Specifications

General IconGeneral
BrandDelta
ModelDVP-EX2
CategoryController
LanguageEnglish

Related product manuals