Chapter 5 Parameters|VFD-B-P Series
Revision April 2009, SW V1.00 5-41
02 - 09
Accel/Decel Rate of Change of UP/DOWN Operation with
Constant Speed
Unit: 0.01
Settings 0.01~1.00 Hz/ms Factory Setting: 0.01
These parameters determine the increase/decrease of the master frequency when operated
via the Multi-Function Inputs when Pr.04-04~Pr.04-09 are set to 11 (Up command) or 12
(Down command).
Pr.02-08 is set to 00: to increase/decrease frequency command according to the setting of
accel./decel.. (only valid when the AC motor drive is in operation)
Pr.02-08 is set to 01: to increase/decrease frequency command according to Pr.02-09.
02 - 15 Keypad Frequency Command Unit: 0.01
Settings 0.00 ~ 400.00Hz Factory Setting: 60.00
This parameter can be used to set frequency command or read keypad frequency command.