EasyManuals Logo

Delta VFD-EL-W Series User Manual

Delta VFD-EL-W Series
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
Chapter 5 Troubleshooting VFD-EL-W
173
5-14 Affecting Other Machines
An AC motor drive may affect the operation of other machines due to many reasons. Some solutions are
listed below:
High Harmonics at Power Side
You can reduce high harmonics at the power side during running.
1. Separate the power system: use a transformer for the AC motor drive.
2. Use a reactor at the power input terminal of the AC motor drive.
3. If using phase lead capacitors (never on the AC motor drive output!), use serial reactors to prevent
damage to the capacitors from high harmonics.
serial reactor
phase lead capacitor
Motor Temperature Rises
When the motor is a standard induction motor with a fan, the cooling will be insufficient at low speed,
causing the motor to overheat. In addition, high harmonics at the output increases copper and core
losses. Use the following measures depending on load and operation range.
1. Use a motor with independent ventilation (forced external cooling) or increase the motor rated
power.
2. Use a special inverter-duty motor.
3. Do NOT run at low speed for long periods of time.

Other manuals for Delta VFD-EL-W Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-EL-W Series and is the answer not in the manual?

Delta VFD-EL-W Series Specifications

General IconGeneral
BrandDelta
ModelVFD-EL-W Series
CategoryDC Drives
LanguageEnglish

Related product manuals