Chapter 4 ParametersVFD-EL-W
63
Output Signal at Low Voltage
When low voltage is detected after the motor detects the P-N voltages, the drive gives a signal for an
external system or control wiring.
Applications
Purpose
Related Parameters
General application
Provide a signal for operation
status
Pr.03.00
Output Signal at Desired Frequency
When the drive's output frequency reaches the desired frequency, it gives a signal for an external system
or control wiring.
Applications
Purpose
Related Parameters
General application
Provide a signal for operation
status
Pr.03.00–03.02
Output Signal for Base Block
When the drive executes a Base Block, it gives a signal for an external system or control wiring.
Applications
Purpose
Related Parameters
General application
Provide a signal for operation
status
Pr.03.00
Overheating Warning for IGBT or Heat Sink
When the heat sink overheats, it gives a signal for an external system or control wiring.
Applications
Purpose
Related Parameters
General application
Safety measure
Pr.03.00