EasyManuals Logo

Delta VFD-EL-W Series User Manual

Delta VFD-EL-W Series
217 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
Chapter 4 ParametersVFD-EL-W
63
Output Signal at Low Voltage
When low voltage is detected after the motor detects the P-N voltages, the drive gives a signal for an
external system or control wiring.
Applications
Purpose
Related Parameters
General application
Provide a signal for operation
status
Pr.03.00
Output Signal at Desired Frequency
When the drive's output frequency reaches the desired frequency, it gives a signal for an external system
or control wiring.
Applications
Purpose
Related Parameters
General application
Provide a signal for operation
status
Pr.03.00–03.02
Output Signal for Base Block
When the drive executes a Base Block, it gives a signal for an external system or control wiring.
Applications
Purpose
Related Parameters
General application
Provide a signal for operation
status
Pr.03.00
Overheating Warning for IGBT or Heat Sink
When the heat sink overheats, it gives a signal for an external system or control wiring.
Applications
Purpose
Related Parameters
General application
Safety measure
Pr.03.00

Other manuals for Delta VFD-EL-W Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-EL-W Series and is the answer not in the manual?

Delta VFD-EL-W Series Specifications

General IconGeneral
BrandDelta
ModelVFD-EL-W Series
CategoryDC Drives
LanguageEnglish

Related product manuals