Chapter 5 Parameters_VFD-B Series 
5-88   
Revision 10/2005, BE13, SW V4.08 
08 - 17 
Software Braking Level 
(the Action Level of the Braking Resistor) 
Unit: 1
  Settings  230V series: 370 to 430V  Factory Setting: 380
    460V series: 740 to 860V  Factory Setting: 760
    575V series: 925 to 1075V  Factory Setting: 950
This parameter sets the DC-bus voltage at which the brake chopper is activated. 
This parameter will be invalid for models above 15kW/20hp for which VFDB brake unit must be used. 
 
08 - 18 
Base Block Speed Search 
      Factory Setting: 00
  Settings  00  Speed search starts with last frequency command 
    01  Speed search starts with minimum output frequency (Pr.01-05) 
This parameter determines the AC motor drive restart method after External Base Block is enabled. 
 
Output fre qu ency
(H)
Ou tput voltage
(V)
FW D Run
B.B.
1
5
2
3
4
Fig 1: B.B. Spee d Search w ith La st Output Freq uency Downw ard Timing Chart
08-06
Base block time for
spe ed search
outp ut current
A
Time
1
2
Stop output voltage
3
Disable B.B. signal
4
Waiting time 08-06
Speed search
6
6
Synchronization speed detection
5
08-07
Current Limit for
Speed Search