Chapter 5 Parameters_VFD-B Series 
Revision 10/2005, BE13, SW V4.08    5-19 
Motor power switch-over between AC motor drive and commercial power 
Applications  Purpose  Functions 
Related 
Parameters
Windmills, pumps, 
extruders 
Switching motor power 
between AC motor drive 
and commercial power 
When switching motor power between 
C motor drive and commercial power, it 
is unnecessary to stop motor or start by 
commercial power with heavy duty 
before switching to by AC motor drive 
control 
03-00 
03-01 
03-02 
03-03 
Energy Saving 
Applications  Purpose  Functions 
Related 
Parameters
Punching machines and 
precision machinery 
Energy saving and less 
vibrations 
Energy saving when the AC motor drive 
runs at constant speed, yet full power 
acceleration and deceleration For 
precision machinery it also helps to 
lower vibrations. 
08-15 
Multi-step Operation 
Applications  Purpose  Functions 
Related 
Parameters
Conveying machinery 
Cyclic operation by multi-
step speeds. 
To control 15-step speeds and duration 
by simple contact signal. 
04-04~04-09
05-00~05-14
Switching acceleration and deceleration times 
Applications  Purpose  Functions 
Related 
Parameters
Auto turntable for 
conveying machinery 
Switching acceleration and 
deceleration times by 
external signal 
Switching multi-step 
acceleration/deceleration by external 
signal. When an AC motor drive drives 
two or more motors, it can reach high-
speed but still start and stop smoothly. 
01-09~01-12
01-18~01-21
04-04~04-09