Appendix B  Accessories_VFD-B Series 
B-2    Revision 10/2005, BE13, SW V4.08 
Applicable 
Motor 
Voltage 
hp  kW 
Full 
Load 
Torque 
Nm 
Resistor value 
spec for each 
AC Motor 
Drive 
Braking Unit
Model VFDB
No. of Units 
Used 
Braking Resistors 
Model and No. of 
Units Used 
Braking 
Torque  
10%ED 
Min. Equivalent 
Resistor Value 
for each AC 
Motor Drive 
60  45  24.745 
9600W 13.6Ө 
4045  1 
BR1K2W6P8 8 
125 
13.6Ө 
75  55  31.11 
12000W 10Ө 
4030  2 
BR1K5W005 8 
125 
10Ө 
 
100  75  42.7 
19200W 6.8Ө 
4045  2 
BR1K2W6P8 16 
125 
6.8Ө 
1  0.75  0.427 
300W 400Ө 
 
BR300W400 1   
200Ө 
2  1.5  0.849 
300W 250Ө 
 
BR300W250 1   
200Ө 
3   2.2  1.262 
400W 150Ө 
 
BR400W150 1   
130Ө 
5   3.7  2.080 
400W 150Ө 
 
BR400W150 1   
130Ө 
7.5  5.5  3.111 
500W 100Ө 
 
BR500W100 1   
82Ө 
10  7.5  4.148 
500W 100Ө 
 
BR500W100 1   
82Ө 
575V Series 
15  11  6.186 
500W 100Ө 
 
BR500W100 1   
82Ө 
 
NOTE
 
1.  Please select the factory setting resistance value (Watt) and the duty-cycle value (ED%). 
2.  If damage to the drive or other equipment are due to the fact that the braking resistors and the braking 
modules in use are not provided by Delta, the warranty will be void. 
3.  Take into consideration the safety of the environment when installing the braking resistors. 
4.  If the minimum resistance value is to be utilized, consult local dealers for the calculation of the Watt figures. 
5.  Please select thermal relay trip contact to prevent resistor over load. Use the contact to switch power off 
to the AC motor drive! 
6.  When using more than 2 braking units, equivalent resistor value of parallel braking unit can’t be less than 
the value in the column “Minimum Equivalent Resistor Value for Each AC Drive” (the right-most 
column in the table). 
7.  Please read the wiring information in the user manual of braking unit thoroughly prior to taking into 
operation.