Chapter 2 Installation and Wiring_VFD-B Series 
2-26   
Revision 10/2005, BE13, SW V4.08 
NOTE
 
If a filter is required for reducing EMI (Electro Magnetic Interference), install it as close as possible to 
AC drive. EMI can also be reduced by lowering the Carrier Frequency. 
When using a GFCI (Ground Fault Circuit Interrupter), select a current sensor with sensitivity of 
200mA, and not less than 0.1-second detection time to avoid nuisance tripping. 
 
DANGER!
 
Damaged insulation of wiring may cause personal injury or damage to circuits/equipment if it comes in contact 
with high voltage.