Chapter 5 Parameters_VFD-B Series 
Revision 10/2005, BE13, SW V4.08    5-3 
Parameter  Explanation  Settings 
Factory 
Setting
Customer
a00-05  User-Defined Coefficient K  0.01 to 160.00  1.00   
00-06  Software Version  Read-only   #.##   
00-07  Password Input  00 to 65535  00   
00-08  Password Set  00 to 65535  00   
00: V/f Control 
01: V/f + PG Control 
02: Vector Control 
00-09  Control Method 
03: Vector + PG Control 
00 
 
00-10  Reserved 
 
Group 1 Basic Parameters 
Parameter  Explanation  Settings 
Factory 
Setting
Customer
01-00 
Maximum Output Frequency 
(Fmax) 
50.00 to 400.00 Hz  60.00 
 
01-01 
Maximum Voltage Frequency 
(Fbase) 
0.10 to 400.00 Hz  60.00 
 
230V series: 0.1V to 255.0V  220.0 
460V series: 0.1V to 510.0V  440.0 
01-02  Maximum Output Voltage (Vmax) 
575V series: 0.1V to 637.0V  575.0 
 
01-03  Mid-Point Frequency (Fmid)  0.10 to 400.00 Hz  0.50   
230V series: 0.1V to 255.0V  1.7 
460V series: 0.1V to 510.0V  3.4 
01-04  Mid-Point Voltage (Vmid) 
575V series: 0.1V to 637.0V  4.8 
 
01-05 
Minimum Output Frequency 
(Fmin) 
0.10 to 400.00 Hz  0.50 
 
230V series: 0.1V to 255.0V  1.7 
460V series: 0.1V to 510.0V  3.4 
01-06  Minimum Output Voltage (Vmin) 
575V series: 0.1V to 637.0V  4.8 
 
01-07  Output Frequency Upper Limit  1 to 120%  100   
01-08  Output Frequency Lower Limit  0 to100 %  0   
a01-09  Accel Time 1  0.01 to 3600.0 sec  10.0   
a01-10  Decel Time 1  0.01 to 3600.0 sec  10.0   
a01-11  Accel Time 2  0.01 to 3600.0 sec  10.0   
a01-12  Decel Time 2  0.01 to 3600.0 sec  10.0   
01-09 ~ 01-12:  Factory setting for models of 30hp (22kW) and above is 60sec. 
a01-13  Jog Acceleration Time  0.1 to 3600.0 sec  1.0