18
1.3. Error display
Seethefollowingtableforeach"Errorinformation"displayanditscontents(status).
Displayorderis
q
,
w
,
e
,
r
,
t
.
Condition State State
q
Sub-μcomNG NoresponsefromSub-μcom
S U B E R R O R 0 1
w
DIRNG NoresponsefromDIR
D I R E R R O R 0 1
e
DSPNG
WhenDSPboot,executingDSPresetmakesnochangetoDSP1FLAG0
port"H".
D S P E R R O R 0 1
NochangetoDSPFLAG0port"H"beforeissuingDSPcommand.
D S P E R R O R 0 2
WhenDSPdataread,executingWRITE="L"makesnochangetoACK="H".
D S P E R R O R 0 3
WhenDSPdataread,executingREQ="L"makesnochangetoACK="L".
D S P E R R O R 0 4
WhenDSPdatawrite,executingWRITE="H"makesnochangetoACK="H".
D S P E R R O R 0 5
WhenDSPdatawrite,executingREQ="L"makesnochangetoACK="L".
D S P E R R O R 0 6
WhenDSPspecialcodeboot,executingDSPresetmakesnochangeto
DSPFLAG0port"H".
D S P E R R O R 1 1
NochangetoDSPFLAG0port"H"beforeissuingDSPspecialread
command.
D S P E R R O R 1 2
NochangetoDSPFLAG0port"H"beforeDSPversionread.
D S P E R R O R 1 3
r
EEPROMNG ErrorappearedinEEPROMchecksum.(***isablockaddressnumber.)
E 2 P R O M E R R * * *
t
BothSUB/DSP
/EEPROMOK
(Noerrordisplay,versiondisplayonly)

Table of Contents

Other manuals for Denon AVR-3311CI