52
Error
Code
Details of Error code Display Coping strategies
0D
Data acquisition failed (timed out)
when downloading Main CPU
rmware. Received Package
Version is wrong.
C o n n e c t i o n f a i l
0 D
Check the network connection.
Carry out the update in an environment
that has little network load.
10
Main CPU failed to receive rmware
for rewriting sent from
DM860 (when timed out).
M a i n * * * m i n
U p d a t i n g f a i l 1 0
Turn the power off then back on.
Updating starts automatically.
11
Main CPU failed to receive rmware
for rewriting sent from DM860 (when
an error )
M a i n * * * m i n
U p d a t i n g f a i l 1 1
Turn the power off then back on.
Updating starts automatically.
12
There was invalid data in the
rmware for rewriting sent from
DM860 to Main CPU (when a
Check Sum error).
M a i n * * * m i n
U p d a t i n g f a i l 1 2
Turn the power off then back on.
Updating starts automatically.
13
The deletion of block data failed
before rewriting Main CPU.
M a i n * * * m i n
E r a s e f a i l 1 3
Turn the power off then back on.
Updating starts automatically.
14
The rewriting of block data failed
when rewriting Main CPU.
M a i n * * * m i n
U p d a t i n g f a i l 1 4
Turn the power off then back on.
Updating starts automatically.
15
The data verication was invalid
after rewriting Main CPU.
M a i n * * * m i n
U p d a t e C h e c k N G 1 5
Turn the power off then back on.
Updating starts automatically.
36
Log-in to DPMS has failed when
rewriting rmware such as Sub
CPU, DSP, FPGA, and PLD.
L o g i n f a i l e d
3 6
Carry out the update in an environment
that has little network load.
37
Line, etc., is busy when logging
into DPMS when rewriting rmware
such as Sub CPU, DSP, FPGA, and
PLD.
S e r v e r i s b u s y
3 7
Carry out the update in an environment
that has little network load.
38
Connection to DPMS failed when
rewriting rmware such as Sub
CPU, DSP, FPGA, and PLD.
C o n n e c t i o n f a i l
3 8
Check the network connection.
Carry out the update in an environment
that has little network load.
39
Connection to DPMS timed out
when rewriting rmware such as
Sub CPU, DSP, FPGA, and PLD.
C o n n e c t i o n f a i l
3 9
Check the network connection.
Carry out the update in an environment
that has little network load.
3A
Error (NG) message received
when downloading rmware when
rewriting Main CPU.
D o w n l o a d f a i l
3 A
Turn the power off then back on.
Updating starts automatically.
Carry out the update in an environment
that has little network load.
3B
Error (line congestion) message
received when downloading
rmware when rewriting Main CPU.
D o w n l o a d f a i l
3 B
Turn the power off then back on.
Updating starts automatically.
Carry out the update in an environment
that has little network load.
3C
Error (connection failure) message
received when downloading
rmware when rewriting Main CPU.
D o w n l o a d f a i l
3 C
Turn the power off then back on.
Updating starts automatically.
Carry out the update in an environment
that has little network load.
50
Log-in to DPMS has failed when
rewriting rmware such as Sub
CPU, DSP, FPGA, and PLD.
S u b * * * m i n
L o g i n f a i l e d 5 0
Carry out the update in an environment
that has little network load.
51
Line, etc., is busy when logging
into DPMS when rewriting rmware
such as Sub CPU, DSP, FPGA, and
PLD.
S u b * * * m i n
S e r v e r i s b u s y 5 1
Carry out the update in an environment
that has little network load.