1.10. About the error code
See the table below for error codes and details of faults when the rmware is updated through USB memory.
Error
Code
Details of Error code Display Coping strategies
01
Unable to detect USB.
C o n n e c t i o n F a i l 0 1
Disconnect and connect the USB
memory.
02
No FirmwareFile in USB.
F i l e s N o t F o u n d 0 2
Make sure that the FirmwareFile is in
the USB memory.
03
FirmwareFile in USB for unsup-
ported Model name/area.
N o t M a t c h F i r m 0 3
Check the supported Model name/area
for the FirmwareFile.
04
Failed to obtain individual Firm-
ware information.
C o n n e c t i o n F a i l 0 6
Start the USB Update again.
05
TimeOut while obtaining individual
Firmware information.
C o n n e c t i o n F a i l 0 7
Start the USB Update again.
06
Failed to obtain entire Firmware
information.
C o n n e c t i o n F a i l 0 4
Start the USB Update again.
07
TimeOut while obtaining entire
Firmware information.
C o n n e c t i o n F a i l 0 5
Start the USB Update again.
08
Error notication received while
requesting FirmwareInfo.
C o n n e c t i o n F a i l 0 8
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for ve seconds.
09
TimeOut while obtaining Firmware
information.
C o n n e c t i o n F a i l 0 9
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for ve seconds.
0A
Unable to detect USB for Firm-
wareDownload.
C o n n e c t i o n F a i l 0 A
Disconnect and connect the USB
memory.
0B
No FirmwareFile for Firmware-
Download.
F i l e s N o t F o u n d 0 B
Disconnect and connect the USB
memory.
0D
Received value with invalid
PackageVersion.
C o n n e c t i o n F a i l 0 D
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for ve seconds.
10
No UpdatePacket received from
CX870 (TimeOut).
U p d a t i n g f a i l 1 0
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for ve seconds.
11
Abnormal data in UpdatePacket
received from CX870 (FormatEr-
ror).
U p d a t i n g f a i l 1 1
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for ve seconds.
12
Abnormal data in UpdatePacket
received from CX870 (CheckSum-
Error).
U p d a t i n g f a i l 1 2
This unit automatically retries several
times. Wait until the FL display stops.
If the FL display stops at the Error dis-
play, press and hold the "Power opera-
tion" button for ve seconds.
63