17
DHT-FS5
ERROR CODES
1. DIAGNOSTICS ERRORS
The set performs a system diagnostic test after power on. All peripheral ICs are checked. If one or more ICs are failing, the
display will flash the following message:
Er
When pressing the mains switch, the display will show which IC is failing. Multiple ICs might be indicate:
1 = M24C02
2 = AK4113
3 = TAS5086
4 = (not used)
5 = M25P20
6 = DSP
2. AMPLIFIER SHUT-DOWN ERROR
When amplifier shut-down occurs, following error will flash:
C1
3. AMPLIFIER DC ERROR
When amplifier DC error occurs, following error will flash:
C2
4. AMPLIFIER OVER TEMPERATURE ERROR
When amplifier is too hot, following error will flash:
C3
エラーコード
1.自己診断エラー
DHT-FS5 は電源を ON にすると自己システム診断を行う。全ての周辺 IC を診断し、IC に不都合を検出すると、
Er を点滅表示する。
Er
フロントパネルの電源ボタンを押すと、不都合のあった IC が下記のように表示される。
複数の IC に不都合があった場合は、該当する IC が同時に表示される。
1=M24C02
2=AK4113
3=TAS5086
4=(not used)
5=M25P20
6=DSP
2.アンプシャットダウンエラー
アンプがシャットダウンした場合、C1 が点滅表示する。
C1
3.アンプDC エラー
アンプに DC エラーが発生した場合、C2 が点滅表示する。
C2
4.アンプ温度超過エラー
アンプが過熱した場合、C3 が点滅表示する。
C3

Other manuals for Denon DHT-FS5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Denon DHT-FS5 and is the answer not in the manual?

Denon DHT-FS5 Specifications

General IconGeneral
TypeHome theatre speakers
Frequency range80 - 20000 Hz
Dimensions (WxDxH)750 x 138 x 118 mm
Satellite speaker driver diameter3.15 \
Audio output channels5.0 channels
Impedance6 Ω
RMS rated power150 W
Signal-to-Noise Ratio (SNR)100 dB
Microphone inYes
Product colorBlack
Weight and Dimensions IconWeight and Dimensions
Weight5100 g

Related product manuals