FEEDING TECHNOLOGY
23
7 Error messages / Operational status
If any errors or malfunctions occur during operation then an error message is displayed on screen.
The following errors could occur:
NOTE:
Errors are only displayed if the relevant accessories are present.
FAULT REASON SOLUTION
RAIL SCREW SENS
The inlet control has not
recognised a part for 60 seconds.
No part has been recognised once
part assembly has begun.
HOSE SCREW SENS
The part presence control has not
recognised any parts after three
reloads.
If necessary refill the bin,
Remove any parts which are
jammed in the guide rail, separator
or feed hose.
Check machine for dirt, sticky
patches or abrasive wear and if
required clean using air pressure or
a clean cloth (only use degreaser
on uncoated bins).
Never grease a construction
groups.
FILL LEVEL
The bowl is empty or not filled
sufficiently.
Refill the vibratory bowl manually
and if required check linear hopper
for sufficient feed parts.