Operating Instruction Booklet
- Translation of the original instruction -
Sequence Controller
AST6 428001 A
NOTICE ALL DOCUMENTATIONS !
Before beginning work this operating instruction booklet and the enclosed
safety instructions (no. 016000, pink-colored booklet) have to be read through
carefully. Always follow the instructions during operation. Give this operating in-
struction booklet and the appropriate safety instructions to the operator.

Table of Contents

Questions and Answers

  • L
    lauramyersAug 18, 2025
    What to do if the Deprag AST6 shows temperature too high?
    • J
      James JohnstonAug 18, 2025
      If the Deprag Controller indicates that the temperature is too high, first examine the screw process and make adjustments as necessary. If the problem persists, it is recommended to consult with the DEPRAG Service Department.
  • D
    daviddillonAug 20, 2025
    What to do if Deprag AST6 says 'Fieldbus not available'?
    • B
      Beth HughesAug 21, 2025
      If the Deprag Controller displays 'Fieldbus not available!', verify that the fieldbus module is correctly installed and tightly mounted. If you no longer need to use the fieldbus module, you can deactivate it in the settings.
  • S
    Stephanie WatsonAug 23, 2025
    What to do if Deprag AST6 Controller shows power unit not found?
    • T
      Travis GarciaAug 23, 2025
      If the Deprag Controller displays 'Power unit not found', switch off the AST6 and then switch it on again. If the fault persists, it is recommended to contact the DEPRAG Service Department.
  • R
    Robert SmithAug 26, 2025
    What to do if Deprag Controller shows no connection?
    • K
      Kathy WilliamsAug 26, 2025
      If the Deprag Controller displays 'No connection', switch off the AST6 and then switch it on again. If the fault remains, please contact the DEPRAG Service Department.
  • J
    Jerry HarrisonAug 28, 2025
    What to do if Deprag AST6 shows no connection to fieldbus?
    • H
      Hannah ThompsonAug 28, 2025
      If the Deprag Controller displays 'No connection to fieldbus!', switch off the AST6 and then switch it on again. If the fault remains, it is recommended to contact the DEPRAG Service Department.
  • M
    Mr. Eric ThomasAug 30, 2025
    What to do if Deprag Controller says screwdriver and controller are not compatible?
    • S
      Steve EvansAug 30, 2025
      If the Deprag Controller indicates that the screwdriver and controller are not compatible, ensure that you have fitted an installation screwdriver to the AST6.
  • C
    Carrie PhillipsSep 2, 2025
    What to do if Deprag AST6 says SSC driver could not be loaded?
    • C
      Craig ValenciaSep 2, 2025
      If the Deprag Controller displays 'SSC driver could not be loaded!', switch off the AST6 and then switch it on again.
  • K
    Karen JonesSep 4, 2025
    What to do if Deprag AST6 Controller says lost settings, default values will be loaded?
    • L
      Lawrence ValenzuelaSep 4, 2025
      If the Deprag Controller displays 'Lost settings, default values will be loaded', check the settings and adjust them if necessary.
  • N
    nelsonericSep 7, 2025
    What to do if Deprag Controller displays position indicator index signal not found?
    • J
      jillian72Sep 7, 2025
      If the Deprag Controller displays 'Position indicator index signal not found', ensure that the drive of the EC screwdriver can be turned freely. Then, restart the AST6.
  • S
    sandovalalexSep 9, 2025
    What to do if Deprag Controller shows "SYS_IO" output overloaded?
    • Z
      Zachary OrtegaSep 9, 2025
      If the Deprag Controller displays '"SYS_IO" output overloaded', check the connections at the I/O interface.

Summary

Safety Instructions

Intended Use

Hardware Description

Interface Description

Details the various connectors and their functions on the AST6 for communication and power.

Commissioning

Assembly Instruction

Step-by-step guide for installing the AST6 sequence controller.

Connection to a master controller

Details how to connect the AST6 to external control systems via I/O or fieldbus.

Operation

Operating via the Touch Display

Explains usage of the touch display, including controls, menus, and input methods.

Operation via the Web Interface

Guide to operating the AST6 using a web browser, including setup and navigation.

Settings

Screwing Samples and Commands

Diagnosis

Maintenance and Servicing

Updating the Software

Instructions for updating the AST6 software.

Error Display and Troubleshooting

System Errors

General overview of system errors and troubleshooting steps.

Error in the Screwing Sequence

Details specific errors that can occur during a screwing sequence.

Trouble Shooting

Decommissioning and storage

Deprag AST6 Specifications