14.2 Error in the Screwing Sequence
Number Displayed text Meaning Troubleshooting
0 OK
No error, the screwing application
was ended properly
-
1 Timeout
The set monitoring time of the
screwing level has been exceeded
2 Angle below target
The indicated minimum angle of
the screwing level was not
reached
3 Angle exceeded
The set maximum angle of the
screwing level has not been
reached
4 Torque not reached
The indicated minimum torque of
the screwing level was not
reached
5 Torque exceeded
The set maximum torque of the
screwing level has been exceeded
Check the screw process and
adapt the program if required.
6
Power unit: Invalid
program
An invalid program was
transmitted to the Power unit
Transfer the program over again.
7
To many E/A
commands
The program contains too many
E/A commands
Check the screwdriver program.
8 reserved - -
9 Invalid program
Program is not valid (does not
exist, or was created for another
screwdriver)
Check the program and adapt if
required or select a different
program.
10 Abort
The start signal has been reset
prior to the normal end of the
screwing application.
The start signal must be present
until the end of the screwdriver
operation.
11 Over current
Current exceeds maximum
permissible value
Check the screw process and
adapt if required.
If necessary please contact
DEPRAG Service.
12
Error during holding
torque
While holding the torque the
moment dropped at the end below
the target torque
Check the screw process and
adapt the program if required.
13 Power unit: Write error Error while writing the program Transfer the program over again.
14
Power unit not
initialized.
Power element not initialized with
screwdriver data.
Switch the cordless EC-
screwdriver on again.
15
Fault during position
hold
Fault during position hold, position
could not be loaded
16 Friction torque undercut
Friction torque in monitored
window too small
17
Friction torque
exceeded
Friction torque in monitored
window too large
Check the screw process and
adapt the program if required.
18 I²t - overload
Overload of the tool via a defined
time frame
Check the screw process and
adapt if required. If necessary
please contact DEPRAG Service.
19 General fault general fault -
Table 22: Fault in the Screwing Sequence