Model FP-700
FP-700 Instruction Manual Rev. 5.1 Page 41 of 46
Operating Temperature: -40°F to +167F°; -40°C to +75°C
Operating Humidity: 0-99% RH (Non-condensing)
Operating Pressure: +/- 10% of Ambient Pressure (ie. 13.2 16.2 psig)
Air Velocity Limits: < 6 meters/second
Storage Specifications
Storage Temperature: -40°F to +167F°; -40°C to +75°C
Storage Humidity: 0-99% RH (Non-condensing)
Storage Pressure: 10 – 16 psig
Storage Duration: For detectors and all associated parts 10 years
Mechanical Specifications
Dimensions: Sensor Assembly Only
7.8H x 2.125Dia.; 198mmH x 54mm Dia.
Stainless Steel Junction Box
12.5H x 6.1W x 4D; 317mmH x 155mmW x 101mmD
Mounting holes (J-box) 5.5; 140mm center to center
Aluminum Junction Box
13H x 6.1W x 4D; 330mmH x 155mmW x 101mmD
Mounting holes (J-box) 5.5; 140mm center to center
Mini Stainless Steel Junction Box
11H x 4.24W x 3.5D; 279mmH x 108mmW x 89mmD
Mounting holes (J-box) 3.5; 89mm center to center
Weight: 2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
5 lbs; 2.27kg (w/mini stainless steel j-box)
Electrical Specifications
Power Input: 11-30VDC
Power Consumption: Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
Inrush current: 1.0A @ 24V
RFI/EMI Protection: Complies with EN50270:2006
Analog Output: Linear 4-20mA DC current (1000 ohms maximum loop load @ 24VDC)