Details the Detcon Model TP-700 H2S sensor, its detection ranges, LED display, and output signals.
Explains the Intelligent Transmitter Module (ITM) components, including microprocessor and I/O protection.
Describes the four main parts of the TP-700 sensor assembly and their construction materials.
Covers the field-replaceable H2S sensor, its gold-plated connections, and warranty.
Provides essential safety instructions for installing the sensor in ATEX-classified hazardous areas.
Discusses critical factors for selecting optimal sensor locations to ensure safe and accurate gas detection.
Lists common airborne substances and gases that can affect sensor performance, including interference data.
Guides on threading the sensor assembly into enclosures and proper mounting orientation for optimal viewing.
Explains correct electrical installation procedures according to codes, emphasizing water leakage prevention.
Details the required conductor connections for power, 4-20mA output, and RS-485 serial interface.
Provides cautions and initial steps for powering up the sensor assembly after installation.
Outlines procedures to verify sensor sensitivity to H2S gas after initial setup and warm-up period.
Explains how to use the magnetic programming tool to interact with the sensor's menu switches.
Describes the menu-driven interface using magnetic switches and lists the main menu categories and sub-menus.
Details the ITM display behavior, fault reporting, and the 4-20mA and Modbus outputs during normal use.
Explains the process, requirements, and materials for performing span calibration using the AutoSpan function.
Introduces Program Mode for checking and adjusting parameters, listing its available sub-menus.
Guides on how to navigate through menu items and select them using the programming magnet.
Details how to view current configuration and operational parameters like sensor type, range, and life.
Explains how to set the span gas concentration level for accurate sensor calibration.
Describes how to change the full-scale detection ranges of the sensor (e.g., 0-20ppm).
Guides on setting the Modbus™ serial ID address for device polling and identification.
Explains how to set the sensor heater power, necessary after sensor replacement or factory reset.
Details how to perform a simulated 4-20mA and Modbus output check for system testing and troubleshooting.
Explains how to reset the sensor to factory default settings and the implications for configuration.
Introduces diagnostic and operational features designed for fail-safe operation.
Covers sensor behavior during over-range conditions, calibration status, sensor life, and days since last calibration.
Details the fail-safe design and how diagnostic faults are reported and displayed on the ITM.
Recommends calibration intervals and procedures to prevent AutoSpan Faults.
Details annual inspection points for corrosion, blockages, and water damage on the sensor and housing.
Explains the function and recommended annual replacement of the condensation prevention packet.
Provides step-by-step instructions for safely removing and installing a new plug-in H2S sensor.
Offers detailed instructions for safely removing and installing a new Intelligent Transmitter Module (ITM).
Guides on replacing the entire sensor assembly, including initial calibration requirements.
Details the procedure for replacing the bottom housing, particularly if the flame arrestor is compromised.
Outlines the warranty terms for the ITM electronics and the plug-in H2S sensor, including limitations.
Lists detailed technical specifications for the TP-700 sensor, including ranges, accuracy, and classifications.