55 Gerade
Service and Maintenance
6
55
25 886 0 25 887 1
!
6.4 Combustion Air Filter
6.4.2 Emptying Cyclone Type
Precleaner
Undo wing nut 1 and remove cover 2.
Remove collector bowl 3 from lower section 4
and empty. Clean leaves, straw and other foreign
matter from lower section of precleaner.
Reposition collector bowl 3 onto lower section 4,
fasten cover 2 in place by tightening wing nut 1.
Never fill collector bowl with oil. Replace collector
bowl if damaged.
6.4.3 Cleaning Oil Bath Air Cleaner
Turn engine off and wait about 10 minutes for the
oil to drain from filter housing 1.
Release snap clips 2 and remove oil cup 3
together with filter element 4. If necessary prise
element out with a screwdriver, taking care not to
damage the rubber gasket 5.
Remove dirty oil and sludge. Clean oil cup.
Clean filter element 4 in diesel fuel and allow to
drip-dry.
Clean filter housing 1 if very dirty.
Inspect and replace rubber gasket 5 and 6 if
necessary.
Fill oil cup with engine oil up to the mark (arrow)
(for viscosity, see 4.1.2).
Refit oil cup and element to filter housing and
secure with snap clips.
Never clean air cleaner with gaso-
line. Dispose of cold oil in accord-
ance with environmental regula-
tions!