6.7 Accessories
6.7.4 Ether Starting System
● Before removing the container, clean the con-
tainer support and the top of the solenoid valve.
● Loosen the bracket 1.
● Unscrew the fluid container 2.
● Empty or replace the depressurized fluid con-
tainer.
● Place the container 1 on the solenoid valve 2 and
tighten by hand.
● When mounting, ensure that gasket 3 is seated
correctly.
● Pull in the brackets.
● Check for leaks.
6.7.4.1 Changing the Fluid Container
Before commissioning, leave the
fluid container of the ether starting
system in position for 15 minutes.
Check for leaks. The starting fluid is
inflammable. Ensure that the con-
tainer is not damaged. Prevent foreign substances
from entering the container. The fluid container
must not be stored at temperatures above 50 °C.
!