sysTem assembly wiTHoUT HUmiDifiCaTion
 If your system includes a humidier, please refer to the instructions provided with the
humidier for assembly and operation.
1. Locate the air supply port and heater accessory connector on the bottom of the
SleepCube device. Ensure that each opening has the appropriate soft cover securely
attached.
2. Place the SleepCube on a stable surface such as a nightstand or table. If you wish, you
may also place the device on the floor at the bedside, being careful to place the unit
where it won’t be kicked or stepped on. Ensure that the air inlet in the back of the
device is not blocked by anything such as curtains or bedding.
 Never place the SleepCube system on a soft surface such as a bed or couch during
operation.
 The height of the SleepCube system must always be lower than the
interface mask when using a humidier to prevent water from getting into
the CPAP mask.
3. Insert the power cord into the back of the device. Make sure the power cord is fully
inserted into the connector. Plug the other end of the power cord into the AC wall outlet.
4. Attach the air supply tubing to the air supply interface in the back of the device.
5. Prepare the mask (supplied by your home care provider) by referring to the mask’s
instruction guide.
6. Connect the air supply tubing to the mask.
 The air supply tubing supplied with the device is specially designed to prevent kinking
and allow you to receive optimal airow. Use only the 22 mm diameter, smooth-bore,
kink-resistant tubing supplied with this device or an air supply tubing recommended by
your home care provider.
KeyPaD anD DisPlay
Basic DeVilbiss SleepCube Controls
Name Symbol Function
ON/OFF The ON/OFF button starts and stops the flow of air from the
device.
HEATER
If your SleepCube has a heater/ humidifier attached, these
buttons adjust the heater setting. Increase the setting for more
humidity and decrease the setting for less humidity.
DELAY
The Delay button activates the comfort delay feature and only
functions if this feature has been enabled. To understand how to
set the parameters of this feature, please refer to the Using the
Comfort Delay Feature found on page 11.