DA 42 AFM
Emergency
Procedures
Doc. No. 7.01.05-E Rev. 8 15-Dec-2017 Page 3 - 55
3.8 SMOKE AND FIRE
NOTE
In the event of smoke or fire, prepare to land the airplane
without delay while completing fire suppression and/or smoke
evacuation procedures. If it cannot be visually verified that
the fire has been completely extinguished, whether the smoke
has cleared or not, land immediately at the nearest suitable
airfield or landing site.
NOTE
The cabin hand fire extinguisher is located inside the airplane
passenger compartment on the RH side of the cabin floor
behind the co-pilot seat.
To release the fire extinguisher from of the bracket, it is
necessary to grasp the bottle at the agent-outlet nozzle near
the Y-spring.
3.8.1 ENGINE FIRE ON GROUND
1. ENGINE MASTER .................... both OFF
2. FUEL SELECTOR .................... both OFF
3. ELECT. MASTER ..................... OFF
After standstill:
4. Canopy ............................. open
5. Airplane ............................ evacuate immediately
END OF CHECKLIST