EasyManua.ls Logo

Diamond DA 42 - Other Emergencies

Diamond DA 42
400 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DA 42 AFM
Emergency
Procedures
Doc. No. 7.01.05-E Rev. 8 15-Dec-2017 Page 3 - 59
3.9 OTHER EMERGENCIES
3.9.1 SUSPICION OF CARBON MONOXIDE CONTAMINATION IN THE CABIN
Carbon monoxide (CO) is a gas which is developed during the combustion process. It
is poisonous and without smell. Increased concentration of carbon monoxide gas can
be fatal. The occurrence of CO in the cabin is possible only due to a defect. If a smell
similar to exhaust gases is noticed in the cabin, the following measures should be taken:
1. Cabin heat & defrost ................... OFF
2. Ventilation........................... open
3. Emergency windows ................... open
4. Forward canopy ...................... unlatch, push up and lock in
"cooling-gap“ position
CAUTION
The maximum demonstrated airspeed for emergency opening
the front canopy in flight is 120 KIAS. Do not exceed
120 KIAS.
END OF CHECKLIST

Table of Contents

Related product manuals